  • 50 Channel Linear Vibration Motor Aging Unit

    BK2021 - BaKo Co., Ltd

    The BK2021 50 Channel Linear Vibration Motor Aging Test System was designed to test your linear vibration motors so you know they are working. Load a jig drawer in the jig assembly unit with 10 DUT's. Close the drawer to start testing and begin loading the next of the 5 drawers. When the machine has finished running up to 4 test sequences that you've programmed in, the drawer opens. On the front, a green light tells you the motor is good, a red light tells you there was a short and if there is no light you know there was an open circuit.

  • ESD & Latch-Up Test System

    Thermo Fisher Scientific Inc.

    Identify and help correct ESD and latch-up susceptibility issues on sensitive integrated circuit components prior to full-scale production with the Thermo Scientific™ MK.2-SE ESD and Latch-Up Test System. The MK.2-SE test system provides advanced capabilities to test high pin count IC devices to Human Body Model (HBM) and Machine Model (MM) ESD standards. The system’s pulse delivery design addresses wave form hazards such as trailing pulse and pre-discharge voltage rise, and performs Latch-Up testing per the JEDEC EIA/JESD 78 Method.

  • Vibration Testing Equipment

    Wewon Environmental Chambers Co, Ltd.

    In Wewon, We have 2 powerful Vibration Testing Equipment. The Vibration Testing Equipment A is : EV210H0808VCSusb-E; The Vibration Testing Equipment B is: EV232H0809VCSusb-E. Technical parameters as below blank forms mentioned, The mainly difference is Sine Excitation Force, Frequency Range, Vibration Table’s size. Application for Vibration Test Equipment : The vibration test is to inspire or impact a part or device to see how it reacts in a real environment. The application of vibration test is very extensive, from the circuit board, aircraft, ships, rockets, missiles, automobiles and household appliances and other industrial products.

  • Telecomunication & Electrical Insolation- Continuity-Voltage-MOV Tester(LCD Display)

    1165IN - Standard Electric Works Co., Ltd

    ● Measures insulation (MΩ), Continuity (Ω) , AC and DC voltage● Six insulation test voltages (DCV): 50V, 100V, 125V, 250V, 500V, 1000V● 68x34 mm (2.677x1.338 inch)  large LCD● Function rotary switch design  for easier operation● Intuitive operation for users● User friendly interface● Auto ACV/DCV detection● Audible voltage warning● DAR/PI indication● Backlight function● Automatic circuit discharge● Test insulation at rated voltage into a 1mA load● Auto ranging● Fuse protection● EnerSave function● MOV test function

  • 200 Ampere Micro OHM Meters

    HL-200 - Neutronics Manufacturing Co.

    Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 200 is a direct reading tester, and uses a test current of 200A DC, resulting in true value and accurate measurements. Model HL- 200 adopts digital circuit technique and is used for measuring contact resistance of switch control equipment at test current of 200A DC. The measurements are accurate as the test is highly stable. HL- 200 is a new, fully automatic micro controlled tester that measures contact resistance at 200A DC with built in printer.

  • Test And Measurement

    SL Power Electronics

    Test and measurement equipment can be particularly affected by the quality and performance of power supplies. Electrical noise is a major concern because the speed and accuracy of test equipment rests greatly on its ability to minimize noise and keep it away from the sensitive electronics which sample and report the data that the equipment is designed to measure. Test and measurement systems may be used for validating electronic circuits, testing electronic equipment, analyzing chemical substances, monitoring environmental conditions, or testing discrete components. Test equipment may be portable, in laboratories or on production floors so the environment where the equipment can be used is also critical when selecting a power supply.

  • Polarity Tester

    PT-1 - International Electro-Magnetics, Inc.

    The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Transformer Winding Resistance Meters

    TWA Advanced Series - Amperis sl

    The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • Automotive Solutions

    Circuit Check, Inc.

    One of the most challenging applications in the field of automotive testing is manufacturing electronics. With each successive model year, the number of automated features increases. Every segment of the automotive electronics plays a role in the safety and reliability. These critical applications require high dependability and low maintenance and warranty costs. Our customers don’t have room for error, hardware test systems must perform as designed. Circuit Check provides Automated Test Systems that meet the stringent needs of this marketplace.

  • PXI-2536, 544-Crosspoint, 1-Wire PXI Matrix Switch Module

    778572-36 - NI

    544-Crosspoint, 1-Wire PXI Matrix Switch Module—The PXI‑2536 is a high-density 8x68 PXI matrix switch module that is ideal for routing low-power DC signals in validation test systems of mass produced devices such as semiconductor chips and printed circuit boards (PCBs). Featuring FET relays, the PXI‑2536 offers unlimited mechanical lifetime and switching speeds up to 50,000 crosspoints/s. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • Insulation & Multifunction Tester (LCD Display)

    4102 MF - Standard Electric Works Co., Ltd

    ● Measures Insulation Resistance, voltage (AC-DC) measurements● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● MOV and Gas Arrester Testing.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.

  • HV AC Test Set

    SERIES S400 TYPE RX I O/ I OACP - K&S Engineering and Scientific Ltd

    The output is continuously variable from zero to 10 kV by means of the panel mounted regulator.  An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator.  Primary protection is provided by two panel mounted fuses.  The output is protected by the output trip and a magnetic/hydraulic circuit breaker.

  • HV DC Test Set

    RX30/4P - K&S Engineering and Scientific Ltd

    The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.